Skip to content

Commercial electrician in North Brisbane and Pine Rivers

Fit-outs, lighting, safety switches and fault finding from Tom, an electrician based in Warner serving Pine Rivers and North Brisbane.

In Queensland, the duty to run a shop, office or workshop in an electrically safe way sits with the business itself, and it covers every piece of electrical equipment your staff use. Tom's Air Conditioning & Electrical, based at 10 Jacksonia Drive in Warner, works with small business owners, tenants and property managers across Pine Rivers and North Brisbane. Tom's commercial service list covers office and shop fit-outs, lighting, switchboard upgrades and safety switches, fault finding, test and tag and three-phase power for retail, hospitality, industrial and body corporate premises. After circuit or fit-out work, you receive the certificate of testing and compliance the law requires. Call 0401 456 987 for availability or request a free quote below.

Licence REC 135414.7 from 12 Google reviews

Get a free quote

Tell Tom about the job and he will call you back with a written price.

Free written quote. No call centre, Tom calls you back.

About commercial electrical

Behind most commercial electrical jobs sit three legal questions: who may do the work, what testing your workplace needs, and what paperwork you should keep. Under the Electrical Safety Act 2002, only the holder of an electrical work licence may perform electrical work, and any business that performs it must hold an electrical contractor licence. The Electrical Safety Regulation 2026, which replaced the 2013 Regulation on 1 September 2026 without changing the existing requirements, sets the testing rules for office, service and manufacturing workplaces. This page explains those rules in plain terms, and how Tom works within them on fit-outs, lighting, power and safety switch jobs.

Why Tom's Air Conditioning & Electrical for commercial services

The Electrical Safety Act places the duty squarely on the person running the business: a shop, cafe, salon or office must be conducted in a way that is electrically safe, and every item of electrical equipment used in it must be electrically safe too. The Electrical Safety Regulation 2026 adds a duty to manage electrical risks at the workplace, including risks from how the installation and equipment are maintained and tested. In practice, a frayed kettle cord in the staff room or a power board sitting beside a wash-down sink is the owner's problem to fix, not something to leave for the landlord or the supplier.

For office and service work, such as selling goods from a shop, cooking in a restaurant or running a hairdressing salon, the regulation gives you a choice for plug-in equipment that is moved during normal use, along with extension cords and power boards. Either that equipment is inspected and tested by a competent person, at least every 5 years if it is used only for office work and at least every year otherwise, or it is connected to a safety switch. Fitting safety switches to the socket circuits is a one-off job, but it brings its own duty: each fixed safety switch must be tested immediately after it is connected and then at the intervals set in AS/NZS 3760. Tom can install those safety switches, test them on connection and explain the ongoing schedule for your premises.

Test and tag itself does not legally require an electrician; a competent person with the right training, test instruments and knowledge of AS/NZS 3760 can do it. The case for a licensed electrician is what happens when an item fails. A failed item must be tagged as unsafe and withdrawn from use immediately, and testing that involves dismantling equipment should only be done by a licensed electrical worker. A licensed electrician may also do the dismantling and repair work on failed equipment that a non-licensed tester should leave alone.

Workshops carry stricter rules. Where manufacturing work such as vehicle repair or welding is the main activity, socket-outlets up to 20A within 2.3m of the floor need a fixed safety switch, and plug-in equipment must be tested every 6 or 12 months depending on whether it is double insulated. Tenants who do not control the installation should raise it with the landlord early. Tom works from a single base in Warner and serves the Pine Rivers suburbs, Brendale and Strathpine among them.

Get a free quote

Commercial Electrical: what to know

Extension leads and power boards running across the floor

Many premises end up with more equipment than power points, so registers, coffee machines and computers get fed from daisy-chained leads.

The regulation requires cord extension sets and flexible cables to be located where they are not likely to be damaged, or protected against damage, including damage from liquid.

Tom adds power points where the work actually happens, so leads come off the floor and away from sinks rather than staff working around them.

Test and tag overdue or never done

Owners of small shops and offices are often unaware that moveable equipment, extension cords and power boards fall under a testing schedule.

Unless it is connected to a safety switch, that equipment must be tested at least every year for service work, or every 5 years if used only for office work, and the tag is your evidence it was done.

Test and tag is on Tom's commercial service list; each item that passes is tagged with the test or retest date and the tester's name or licence number, and any failed item is tagged and taken out of use.

Safety switches installed but never tested

Safety switches are often treated as fit-and-forget once they are on the board.

In office and service workplaces, each fixed safety switch must be tested on connection and then at the intervals in AS/NZS 3760, and one that is not working properly must be tagged and withdrawn from use.

Tom tests safety switches when he connects them and explains the ongoing testing schedule your premises needs.

Fit-out wiring offered by an unlicensed trade

During a shop or office fit-out, it can be tempting to let the shopfitter or a handyman move a power point or add a light while they are on site.

Electrical work may only be performed by a licence holder, and a business doing it needs an electrical contractor licence; the maximum penalty is 400 penalty units for each offence.

Tom's business publishes electrical contractor licence REC 13541, which you can check on the WorkSafe Queensland licence search, and he gives you the certificate of testing and compliance after the work is connected.

Workshop socket-outlets without fixed safety switches

Older workshop tenancies may still have socket circuits that predate the current manufacturing work rules.

Where manufacturing work such as vehicle repair or welding is the main activity, socket-outlets up to 20A within 2.3m of the floor must have a fixed safety switch, unless the tenant does not control the installation and cannot get permission.

Once you have the landlord's permission, Tom can install safety switches on the workshop's socket circuits.

No one sure who owns testing in a leased or body corporate building

In a leased shop or a body corporate building, the business, the landlord, the property manager and the body corporate can each assume another party has the testing and paperwork in hand.

The duty to keep equipment electrically safe and to manage electrical risks sits with the business conducting the undertaking. A workshop tenant that does not control the installation and cannot get permission is exempt only from the fixed safety switch requirement, not from the equipment testing duty.

Body corporate work is on Tom's commercial service list; tell him who controls the switchboard and who is commissioning the job, because the certificate of testing and compliance must name the person the work was done for.

The jobs Tom does most

01

Office and shop fit-outs

Electrical work for new and refitted offices and shops, from power points to lighting.

Fit-out wiring must be done under an electrical contractor licence, and once it is connected you are owed a certificate of testing and compliance for your landlord and your records.

Request a free quote

02

Commercial lighting installations

Lighting installation and upgrades for retail, hospitality and office premises.

A lighting upgrade is connected electrical work too, so it comes with the same certificate of testing and compliance as any new circuit.

Request a free quote

03

Safety switches for workplaces

Safety switch installation and testing on workplace socket circuits.

For shops, cafes and offices, safety switches on the socket circuits are the legal alternative to scheduled test and tag of moveable equipment, but the switches themselves must be tested on connection and then to AS/NZS 3760.

Request a free quote

04

Test and tag

Inspection, testing and tagging of plug-in workplace equipment, leads and power boards, as listed on Tom's commercial service list.

Test and tag is on Tom's commercial service list, so ask about it when you call. A failed item must be tagged and withdrawn, and dismantling or repair work on it belongs with a licensed electrical worker.

Request a free quote

05

Three-phase power installations

Three-phase power for commercial equipment and workshops, as listed on Tom's commercial service list.

Three-phase power is on Tom's commercial service list, so ask about it when you call. Separately, where manufacturing work such as vehicle repair or welding is the main activity, socket-outlets up to 20A within 2.3m of the floor need a fixed safety switch.

Request a free quote

06

Maintenance and fault finding

Ongoing electrical maintenance and fault finding for commercial premises.

Finding the fault behind a tripping circuit lets you return equipment to use once it is repaired or tested safe, as the regulation requires.

Request a free quote

A licence number you can look up

Tom's Air Conditioning & Electrical publishes Queensland electrical contractor licence REC 13541, and you can confirm the name and status on the WorkSafe Queensland electrical licence search before any work starts. That check matters for commercial work, because a business that performs electrical work must hold a contractor licence. The business's about page describes Tom as a licensed electrician and air conditioning technician with over 15 years of hands-on experience. He works from a single base at 10 Jacksonia Drive, Warner, serving Bray Park, Strathpine, Lawnton, Brendale, Petrie, Joyner, Cashmere, Eatons Hill, Albany Creek and North Brisbane. Quotes are free, and the business says its pricing is upfront with no hidden fees. Google reviewers, writing about residential air conditioning jobs rather than commercial work, describe Tom as on time, quick to identify the problem, knowledgeable and transparent about pricing.

  • Queensland Electrical Contractor

    Registered electrical contractor in Queensland, licence REC 13541, listed on the Electrical Safety Office licence search.

    Check the licence
  • Smoke alarm compliance

    Smoke alarm installs to the Queensland legislation: photoelectric, interconnected, and to AS 3786.

    Read the Queensland rules

Commercial Electrical questions

Something not covered? Call Tom on 0401 456 987.

Does test and tag have to be done by an electrician in Queensland?

No. Workplace test and tag must be done by a competent person with the training, test instruments and knowledge of AS/NZS 3760, and an electrical licence is not required for that testing. Testing that involves dismantling equipment should be left to a licensed electrical worker. A failed item must be tagged and withdrawn from use, and repairing it is work for a licensed electrician such as Tom.

How often does equipment in my shop or office need test and tag?

For plug-in equipment that is moved during normal use, plus extension cords and power boards, the Electrical Safety Regulation 2026 sets at least every 5 years if the equipment is used only for office work, and at least every year for service work such as a shop, cafe or salon. Where manufacturing is the main work, it is at least yearly if double insulated and at least every 6 months if not. Connecting that equipment to a safety switch is the alternative for office and service work.

Can I fit safety switches instead of doing test and tag?

For office and service work, yes: moveable equipment connected to a safety switch does not need the scheduled test and tag. The safety switches then carry their own duty. Each fixed safety switch must be tested immediately after it is connected and then at the intervals in AS/NZS 3760, and one that is not working properly must be tagged and withdrawn. Tom can install the switches, test them on connection and explain the schedule.

What paperwork should I receive after a fit-out or new circuits?

A licensed electrical contractor who connects an installation after electrical work must give you a certificate of testing and compliance as soon as practicable, naming you as the person the work was done for. Keep it with your lease and maintenance records. If Tom also tests and tags equipment, each passed item carries a tag showing the test or retest date and the tester's name or licence number.

I lease my workshop. Who has to install the safety switches?

Where manufacturing work is the main activity, the business must ensure a fixed safety switch is installed for socket-outlets up to 20A within 2.3m of the floor. A tenant who does not control the installation and cannot get permission from the person who does is exempt from that requirement. Ask your landlord early; once permission is given, Tom can install safety switches on the workshop's socket circuits.

Older guidance quotes the 2013 regulation. Has anything changed?

The Electrical Safety Regulation 2026 commenced on 1 September 2026 and replaced the Electrical Safety Regulation 2013. WorkSafe Queensland says the policy intent and the existing requirements did not change, but the section numbers did, so older checklists and code of practice references may point to the wrong sections. The testing duties described on this page follow the 2026 regulation.

Get a quote for commercial electrical

Tell Tom about the job and he will call you back with a written price.

Sources

Need commercial services?

Planning a fit-out, a lighting upgrade or a round of testing? Tell Tom what kind of premises you run, roughly how many moveable appliances, leads and power boards are in use, and whether you or your landlord controls the switchboard, so the free quote reflects the real job. If the work is better done while the doors are closed, mention it when you call and ask what availability Tom has. Call 0401 456 987, or use the form below.

Call Tom on 0401 456 987